COMPUTER ANALYSIS OF 2D ULTRASONIC IMAGINGS OF HIP DYSPLASIA AND MEASUREMENT OF ITS GEOMETRY

Authors

  • Yosyp Yosypovych Bilynskyi Вінницький національний технічний університет
  • Oleksandr Ivanovych Nikolskyi Вінницький національний  медичний університет
  • Artem Borysovych Huralnyk Вінницький національний технічний університет

Keywords:

2D ultrasound images, computer analysis, NI Vision Assistant, Find Straight Edge, determination of the centers of circles on a binary image, image pre-processing algorithms

Abstract

A review of automated medical image analysis systems for the treatment of hip dysplasia is made. It is shown that the development of computer-aided automation tools for the analysis of ultrasound images and the diagnosis of hip dysplasia is an urgent task. For computer analysis, the base of ultrasound images of the hip joint was selected, for which the diagnosis of dysplasia behind the Graph was done visually manually and automated using computer tools. We analyzed the main types of hip dysplasia behind the Count for computer diagnostics of 2D ultrasound images. It was shown that in ultrasound images the geometric parameters of the hip joint, measured visually by hand, are characteristic of various types of dysplasia. To evaluate the geometric parameters of the hip joint on the images, the NI Vision Assistant package was used as a tool. Algorithms for computer diagnostics of 2d ultrasound images of hip dysplasia have been developed using the operation of determining the centers of circles in a binary image, and using the Find Straight Edge contour extraction algorithm. Algorithm steps using image processing operations in the NI Vision Assistant package are shown. The effectiveness of the Find Straight Edge algorithm has been demonstrated in highlighting the contour of the image edge of the ilium and cartilage of the acetabulum of the hip joint. Information of boundary points found along all lines of search lines in the search area of ​​image elements of the hip joint is shown with parameters STR, TNR, SNR. The operation of automated measurement of α - angle is demonstrated in detail. It was shown in experiments that the algorithm using the Find Straight Edge contour extraction algorithm more accurately measures the α-angle and, accordingly, diagnoses hip dysplasia with higher reliability.

Author Biographies

Yosyp Yosypovych Bilynskyi, Вінницький національний технічний університет

Ph.D., Professor, Department of Electronics and Nanosystems, Vinnitsa National Technical University

Oleksandr Ivanovych Nikolskyi, Вінницький національний  медичний університет

Candidate of Technical Sciences, Associate Professor, Associate Professor, Department of Biophysics of Medical Equipment and Informatics, Vinnitsa National Medical University

Artem Borysovych Huralnyk, Вінницький національний технічний університет

Postgraduate student of the Department of Electronics and Nanosystems, Vinnitsa National Technical University.

References

American College of Radiology: ACR-AIUM practice guideline for the performance of the ultrasound examination for detection and assessment of developmental dysplasia of the hip. /ACR guidelines, 2012.

Overhoff, H., et al., Computer-based determination of the newborn’s femoral head coverage using three-dimensional ultrasound scans, in Medical Image Computing and Computer-Assisted Interventation — MICCAI’98, W. Wells, A. Colchester, and S. Delp, Editors. 1998, Springer Berlin Heidelberg. p. 1024-1031.

García Luis R. Hip joint segmentation from 2D ultrasound data based on dynamic shape priors. / Luis-García, R. and C. Alberola-López// Proceedings of the 4th WSEAS international conference on Electronics, control and signal processing. World Scientific and Engineering Academy and Society (WSEAS), 2005.

Rathi Yogesh. Particle Filtering with Dynamic Shape Priors. Georgia Institute of Technology. / Yogesh Rathi, Samuel Dambreville, Allen Tannenbaum.// - Atlanta, GA [Electronic resource]. – Available: https://www.researchgate.net/publication/27543613_Particle_Filtering_with_Dynamic_Shape_Priors

Garcia Luis. Parametric 3D hip joint segmentation for the diagnosis of developmental dysplasia. in Engineering in Medicine and Biology Society. / Luis-Garcia, R. and C. Alberola-Lopez. // EMBS '06. 28th Annual International Conference of the IEEE. - 2006.

Garcia Luis. Analysis of ultrasound images based on local statistics. / Luis-Garcia, R., Aja-Fernandez S., and Cardenes-Almeida R. // Application to the diagnosis of developmental dysplasia of the hip, in 2007 IEEE Ultrasonics Symposium. 2007. P. 2531-2534.

Chen H.Y. Application of segmentation and measurement in the treatment of developmental dysplasia of the hip. / Chen H.Y., et al. // Bioinformatics and Biomedical Engineering, ICBBE 2007. The 1st International Conference on.. 2007.

Graf R. Hip sonography--how reliable? Sector scanning versus linear scanning? Dynamic versus static examination? / Graf R. // Clin Orthop Relat Res., №281 1992. P. 18-21.

Robben Simon. Developmental Dysplasia of the Hip – Ultrasound / Simon Robben and Robin Smithuis.//: [Electronic resource]. – Available:

http://www.radiologyassistant.nl/en/p54ba2c50995c5/developmental-dysplasia-of-the-hip-ultrasound.html

National Instruments Corporation: [Electronic resource]. – Available: http://www.ni.com/vision/software/vdm/

IMAQ Vision for Visual Basic. User manual. National Instruments Corporation. [Electronic resource]. – Available: http://www.ni.com/pdf/manuals/371257a

Downloads

Abstract views: 333

Published

2019-12-16

How to Cite

[1]
Y. Y. Bilynskyi, O. I. Nikolskyi, and A. B. Huralnyk, “COMPUTER ANALYSIS OF 2D ULTRASONIC IMAGINGS OF HIP DYSPLASIA AND MEASUREMENT OF ITS GEOMETRY”, ІТКІ, vol. 46, no. 3, pp. 4–14, Dec. 2019.

Issue

Section

Biological and medical devices and systems